Description
A specially modified version of our unique water dispersed, liquid synthetic rubber membrane, containing integral linear micro fibre reinforcement. Chemind Newflex-R100 is specifically designed to eliminate blistering and wrinkling that may occur in exposed or ponded situations, as it does not require the general use of reinforcing fabric.
Uses
Newflex-R100 is ideally suited to indoor and outdoor applications, including roofing, box gutters, balconies, sill or window flashings, podium decks, planters, water features, landscaped areas, bathrooms and wet areas.
It can be applied to most prepared surfaces encountered in construction.
Newflex-R100 is suitable for waterproofing of foot traffic areas on balconies, roofs, ramps, plant room floors and stadium concourse or service areas, when used in conjunction with Chemind Tuffcote Duratop coating.
Features
Typical Properties
|
Colour |
Coloured paste |
|
Composition |
Reinforced polymerised monomers |
|
Solids Content |
65% |
|
Service Temperature |
-10°C to 80°C |
|
Application Temperature |
5°C to 30°C |
|
Surface Dry Time |
2 hrs (0.6mm @ 25°C) |
|
Cure Time (Foot Traffic) |
8 hours |
|
Tensile Strength |
1.35 MPa @ 100% Ext |
|
Elongation |
350% |
|
Permeance |
15 g/mm/m²/24 hrs |
|
Accelerated Weathering (ASTM D822A) |
No effect |
Preparation
Surfaces to be waterproofed must be sound, smooth and free from dust, loose matter, oil, grease or other contaminants.
All surface defects shall be repaired using Chemind Chembond modified mortar.
Use Chemind Chemflex PU sealant to fill joints, cracks and form fillets to internal corners or penetrations.
Application
Priming
For internal wet areas, tiled decks, walls, sills or flashings, apply one coat of Chemind Primer "W" or diluted Newflex-R100 at a rate of 6 -10 m²/litre.
For exposed decks, car park slabs, sumps, pits, pools and water features, apply one coat of Chemind Epocote F100W water based epoxy at 6 -10 m²/litre.
Detailing
Detail all joints, cracks, outlets, penetrations and internal corners with a 150mm strip of Chemind Fibreglass Reinforcing Mat bedded between two heavy coats of Newflex and centred over the joint.
Apply a heavy brush coat of Newflex-R100 to all other penetrations, internal corners and shrinkage cracks.
Application of Continuous Membrane
Apply Newflex-R100 membrane liberally by brush, squeegee or roller in two or more flow coats to minimum 1.0mm DFT. Allow to dry fully between coats.
Coating application should be made in a cross direction to previous coat to ensure even coverage.
Surfacing
Newflex-R100 membrane is foot trafficable within 8 hours. Use following systems for specific situations as listed. Apply surfacing materials only to fully cured Newflex-R100.
Coverage
Total consumption for the Newflex-R100 membrane system is approximately 1.25 -1.5 litres/m2.
Packaging
Newflex-R100 is packed in 15 litre plastic pails for the domestic market and in 20 litre metal pails for export.
Shelf Life
Unopened or resealed pails of Newflex-R100 has a shelf life of 2 years, when stored in a dry, cool place.
Clean-up
Remove uncured Newflex-R100 with water. Chemind GP Solvent may assist with the removal of cured product. Exercise care when using solvents. Please review all MSDS before use.